SECTION 15: REMOVAL AND REPLACEMENT PARTS
63 of 85
SECTION 15: REMOVAL AND REPLACEMENT PARTS
See warnings and important information before
removing or replacing parts.
After any maintenance or repair work, always test
fire the heater in accordance with the commissioning
instructions on Page 40, Section 10 to help ensure
all safety systems are in working order before
leaving the heater to operate. Minor faults may be
traced by using the troubleshooting charts on Page
58, Section 14.2 through on Page 62, Section 14.7.
15.1 Burner Components
To re move the burner from the heater:
1. Unplug the burner electrical supply from the
heater.
2. Isolate the fuel supply at the inlet manual valve
and disconnect the inlet fuel pipe.
3. Unscrew the nuts holding the burner mounting
flange to the heater.
4. Remove the bu rner from the heater, retaining
the gasket for reuse.
For removal of burner components, follow the burner
manu
facturer’s instructions. To refit the burner,
reverse the instru ctions above. Fit the gasket
between the burner mounting flange and the heater.
Use a new gasket, if necessary.
15.2 Direct On-Line Main Fan Starter and
Thermal Overload Unit (3 Ø)
This assembly comprises two parts, the contactor
and the overloads, which may be changed
separately.
15.2.1 The Contactor
To re m o ve the contactor:
1. R e m o ve the overloads as on Page 63, Section
15.2.2.
2. Remove the line connections to the top of the
contactor (noting the colour code) and the two
coil connections at the top rear of the contactor.
3. Unscrew the fixing screws to remove the con-
tactor from the panel.
4. Reverse these instructions to refit. Check rota-
tion of the fan after working on the contactor.
15.2.2 The Overloads (models 060 to 100)
To re m o ve the overloads:
1. U n s c r e w the motor connecting wires from their
terminals at the bottom of the assembly. Note
the colour code.
2. Disconnect the overload circuit connections
near the overload reset button.
WARNING
Cut/Pinch Hazard
Wear protective gear during installation,
operation and service.
Edges are sharp.
Failure to follow these instructions can result
in injury.
Carbon Monoxide Hazard
WARNING
Use only genuine ROBERTS GORDON
®
replacement parts per this installation, operation and
service manual.
Failure to follow these instructions can result in death, electric shock, injury or property damage.
Explosion Hazard
DANGER
Electrical Shock Hazard
Fire Hazard
WARNING
Severe Injury Hazard
Use proper lifting practices and equipment.
Equipment and accessories are heavy.
Failure to follow these instructions can result
in death, injury or property damage.