9.8 Wiring Diagram Oil Models 40-50 (floor standing)
1
OIL BURNER 7 WAY PLUG
L1
N
T1
T2
S3
B4
7 POLE SOCKET
GROUND
NEUTRAL
BURNER RUN
LOCK-OUT
LAMP
FLAME LAMP
LIVE
SIGNAL
L1
N
T1
T2
S3
B4
7 POLE PLUG
PACKAGED BURNER
L1
N
T1
T2
S3
B4
L1
N
T1
T2
S3
B4
BROWN
6
R
5
BROWN
RELAY
LOCKOUT
BROWN
BLUE
BROWN
BROWN
BROWN
4
R N.C
P.S N.O
R N.O
21
31
PRESSURE SWITCH
4.8 mbar (1.96" wc)
NOTES:
1. C O NTROL WIRE TO BE A MINIMUM OF 1 mmØ ,FLEXING TYPE.
HAVING A TEMPERATURE RATING OF A LEAST 105°C AND 600 V OR EQUIVALENT.
COLORS 230 VAC: PHASE-BROWN, NEUTRAL-BLUE, GROUND-GREEN/YELLOW.
2. POWER WIRE FROM INPUT AND OUTPUT TERMINALS TO BE A MINIMUM
OF 1mmØ, FLEXING TYPE.
HAVING A TEMPERATURE RATING OF A LEAST 105°C AND 600 V OR EQUIVALENT.
COLORS 400 VAC 3 PH : L1-BROWN , L2-BLACK , L3-GREY AND NEUTRAL-BLUE,
GROUND-GREEN/YELLOW.
3. ALL WIRING SHALL BE IDENTIFIED AT BOTH ENDS, WITH CABLE BEING IDENTIFIED
WITH
THE SAME TERMINAL NUMBER TO WHICH IT IS CONNECTED TO IN THE CONTROL PANEL.
MAIN TERMINALS LOCATED IN CONTROL PANEL.
WIRE(S) LOCATED IN CONTROL PANEL.
WIRE(S) LOCATED IN FIELD.
CONTACTOR
BREAKER 10 AMP
FAN CONTROL (OPTIONAL)
TIME / TEMPERATURE CONTROLS
3
BLUE
BROWN
BROWN
2
BROWN
BROWN
BLACK
GREY
BROWN
BROWN
FAN
LIMIT
BLUE
BROWN
GREEN/YELLOW
BROWN
FAN/LIMIT STAT
400 V
3 ph
50 Hz
M1
M1
T1
T3
T2
MTR
3 PHASE ONLY
MAIN FAN
MOTOR
GREEN/YELLOW
N
L1
L2
L3
NOTE:
Any of the original wire supplied with
the heater must be replaced with wiring
material having a temperature rating of
at least 105°C (221°F) and 600 V.