SECTION 9: WIRING AND ELECTRICAL INFORMATION
35 of 85
9.10 Wiring Diagram Oil Models 40-50 (horizontal mounting)
NOTES:
1. C O NTROL WIRE TO BE A MINIMUM OF 1 mmØ ,FLEXING TYPE.
HAVING A TEMPERATURE RATING OF A LEAST 105°C AND 600 V OR EQUIVALENT.
COLORS 230 VAC: PHASE-BROWN, NEUTRAL-BLUE, GROUND-GREEN/YELLOW.
2. POWER WIRE FROM INPUT AND OUTPUT TERMINALS TO BE A MINIMUM
OF 1mmØ, FLEXING TYPE.
HAVING A TEMPERATURE RATING OF A LEAST 105°C AND 600 V OR EQUIVALENT.
COLORS 400 VAC 3 PH : L1-BROWN , L2-BLACK , L3-GREY AND NEUTRAL-BLUE,
GROUND-GREEN/YELLOW.
3. ALL WIRING SHALL BE IDENTIFIED AT BOTH ENDS, WITH CABLE BEING IDENTIFIED
WITH
THE SAME TERMINAL NUMBER TO WHICH IT IS CONNECTED TO IN THE CONTROL PANEL.
MAIN TERMINALS LOCATED IN CONTROL PANEL.
WIRE(S) LOCATED IN CONTROL PANEL.
WIRE(S) LOCATED IN FIELD.
6
7
RELAY
RED/WHITE
RED/WHITE
BLUE
4
R N.C
21
5
R N.O
31
BROWN
P.S N.O
LOCKOUT
BROWN
BROWN
R1
REMOTE BURNER LOCKOUT LIGHT
RELAY
PRESSURE SWITCH
4.8 MBAR (1.96"W.C)
OIL BURNER 7 WAY PLUG
L1
N
T1
T2
S3
B4
7 POLE SOCKET
GROUND
NEUTRAL
BURNER RUN
LOCK-OUT LAMP
FLAME LAMP
PACKAGED BURNER
LIVE
SIGNAL
L1
N
T1
T2
S3
B4
L1
N
T1
T2
S3
B4
7 POLE PLUG
BLUE
BLUE
BROWN
BROWN
BLUE
BLUE
BLUE
BROWN
R
L1
N
T1
T2
S3
B4
N
L1
BREAKER 10 AMP
FAN CONTROL (OPTIONAL)
TIME / TEMPERATURE CONTROLS
1
3
BROWN
2
L2
L3
M1
T1
T3
T2
MTR
MAIN FAN
MOTOR
BROWN
BROWN
BLACK
GREY
GREEN/YELLOW
BLUE
BROWN
LIMIT
GREEN/YELLOW
CONTACTOR
BLUE
BROWN
M1
R1 N.O
31
BROWN
3 PHASE ONLY
FAN
BROWN
FAN/LIMIT STAT
400 V
3 ph
50 Hz
NOTE:
Any of the original wire supplied with
the heater must be replaced with wiring
material having a temperature rating of
at least 105°C (221°F) and 600 V.